脉冲振荡肺功能与黏附分子在儿童哮喘中的临床意义
DOI:
CSTR:
作者:
作者单位:

作者简介:

通讯作者:

中图分类号:

R562.2+5

基金项目:


Values of impulse oscillometry for pulmonary function and adhesion molecules in childhood asthma
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    目的:脉冲振荡肺功能是近年来开展的一项肺功能测定新技术, 特别适用于学龄前儿童,但目前有关报道不多,且尚无统一正常值。可溶性细胞间黏附分子-1(sICAM-1)、内皮细胞黏附分子-1(sVCAM-1)是已明确的反映哮喘严重程度的指标,该文旨在探讨上述指标在儿童哮喘中的临床意义。方法:应用Master Screen系列肺功能测定系统,对25例健康儿童、40例哮喘发作期儿童用脉冲振荡法(IOS)进行肺功能检测,其中23 例患儿激素治疗达缓解期后再次检测;同时对部分上述儿童(发作期23例,缓解期20例, 对照组16例)进行sICAM-1、sVCAM-1水平检测。 结果:IOS肺功能测试发作期R5,R20,R5-R20,X5,Fres,Zrs均高于对照组和缓解组,差异均有显著性(q= 2.91 ~15.61,P<0.01或P<0.05),缓解期与对照组比较,R5,R5-R20,Fres,Zrs差异有显著性(q=3.08~9.19,P<0.01或 P<0.05)。发作期血清sICAM-1,sVCAM-1明显高于缓解期及对照组(q= 6.23~26.15,P<0.01),而缓解期仍高于对照组(q=16.86,12.46, P<0.01)。发作期sICAM-1,sVCAM-1与R5-R20呈正相关(r=0.45,0.57 P<0.05) 结论:IOS肺功能和sICAM-1、sVCAM-1都可以作为儿童哮喘病情严重程度和治疗效果的评价指标,两者之间有一定的相关性,IOS肺功能测定简便、无创,适合于学龄前儿童。[中国当代儿科杂志,2007,9(5):415-418]

    Abstract:

    OBJECTIVE: Impulse oscillometry (IOS) is a novel technique for the evaluation of pulmonary function. Soluble intercellular adhesion molecule-1 (sICAM-1) and soluble vascular cell adhesion molecule-1 (sVCAM-1) are definitive indicators for the severity of asthma. This study aimed to explore the relationship of IOS pulmonary function with sICAM-1 and sVCAM-1, and their values in childhood asthma. METHODS: IOS via Master Screen System for pulmonary function was performed in 40 children with acute asthma and 25 healthy children. Twenty-three of 40 children with acute asthma were re-tested for IOS pulmonary function at remission. sICAM-1 and sVCAM-1 levels were measured in 23 children with acute asthma, 20 asthmatic children at remission and 16 healthy children. RESULTS: The parameters of IOS pulmonary function, R5, R20, R5-R20, X5, Fres and Zrs in children with acute asthma were significantly higher than in asthmatic children at remission and in normal controls (q= 2.91-15.61, P< 0.01 or 0.05). There were significant differences in R5, R5-R20, Fres and Zrs between the asthmatic children at remission and normal controls (q= 3.08- 9.19, P< 0.01 or 0.05). sICAM-1 and sVCAM-1 levels in children with acute asthma were significantly higher than in asthmatic children at remission and in normal controls (q= 6.23-26.15, P< 0.01). The asthmatic children at remission had higher levels of sICAM-1 and sVCAM-1 than the normal controls (q=16.86, 12.46, P< 0.01). R5-R20 positively correlated with sICAM-1 and sVCAM-1 in children with acute asthma (r=0.45, 0.57, P<0.05). CONCLUSIONS: IOS for pulmonary function and sICAM-1 and sVCAM-1 may be used to evaluate the severity and therapeutic effects of childhood asthma. A correlation exists between IOS pulmonary function and sICAM-1 and sVCAM-1.

    参考文献
    相似文献
    引证文献
引用本文

刘小梅, 车淑玉, 刘向荣, 林荣军.脉冲振荡肺功能与黏附分子在儿童哮喘中的临床意义[J].中国当代儿科杂志,2007,9(5):415-418

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2009-09-08
  • 出版日期:
文章二维码
您是第位访问者
ICP:湘ICP备17021739号-4
中国当代儿科杂志 ® 2025 版权所有
技术支持:北京勤云科技发展有限公司
管理员登录